Hazards Of Power Lines Concrete Pump Trucks Related Information

Keeping out of power lines'way - Concrete Construction

The primary concern when utilizing a pump truck during a pumped concrete pour is safely positioning the truck where the boom can reach the concrete placement site. The key word here is "safely." Improperly positioned, a pump truck can cause death or serious injury, making a nightmare out of what may have appeared to be a standard, "every day" pour.

Concrete Pump Hazards & Safety - Concrete Network

Concrete Pump Hazards & Safety - The Concrete Network

SAFETY PROCEDURES - American Concrete Pumping …

Chapter 1 – Introduction to Power Line Hazards 5 Power Line Myths Myth #1 "Overhead power lines don't carry enough power to hurt you" Reality: Overhead power lines carry voltages ranging from 120 to 750,000 volts. For an electrocution to occur, a path to ground must be created for the current. If your body touches a power source,

Important Change to the 17-Foot Rule | American Concrete

Dec 20, 2010 · The U.S. Department of Labor has made a change to the Federal Code of Regulations regarding crane safety.While concrete pumps are specifically excluded from the new regulations, the hazards for cranes and pumps are similar, including booming into power lines.Like cranes, the number one cause of fatal accidents with pumps is electrocution.

Concrete Pumping Health and Safety Guidelines

stopped the truck under the power line, and the crane operator, not real-izing that the truck had moved out of the safety zone, swung the boom be-hind the truck. A laborer, standing on the ground, grabbed the bucket handle and was electrocuted when the hoist cable hit the power line. The worker was killed. Power lines are the biggest hazard to

Concrete Truck Safety - Southwest Risk Management, LLC

Jul 15, 2015 · Use a spotter when moving the truck with an extended chute. Make sure the chutes are locked in place before moving. Only employees are allowed on or in the vehicle. Concrete Pump Use. When operating a vehicle with a concrete pump, review the following before any work is started: Are the pump specifications adequate to handle the size of the load?

Hazards Of Power Lines & Concrete Pump Trucks

Standards and enforcement policy for construction concrete

eLCOSH : Power Line Hazard Awareness

Power line contacts involving concrete pumps seem to occur during the take-down phase. True or false? If a power line is not de-energized, and barrier protection has D.Q1 been installed on the line, the closest distance that a crane boom or load line can (safely) be to a power line less than 50kV is ____________feet.

Concrete worker killed by dump truck after air pocket

Jul 11, 2021 · A Georgia worker was killed Saturday when an air pocket in a concrete pump truck's piping threw him into the road. Brian Crook, 49, of Piedmont, South Carolina, had just finished pumping

Key Considerations for Working Around Pumps 2016

Ensure concrete pump. concrete pump truck, or crane bucket operator knows that you are on site. 2.2 Look up and all around for electrical lines or power cables that may be or become closer than 17 feet of the concrete pump truck boom or crane and the cable while in operation. (Company policy may dictate additional distance from an energized source.

Standards and enforcement policy for construction concrete

Today, our professionals here at Cole & Lambert would like to discuss the safety precautions that operators need to take when working near power lines.

Concrete pumpers - WorkSafeBC

Concrete pumpers. Concrete pumpers present a number of risks to workers, including hose whips, falls, and contact with power lines. See the following resources and links for information on working safely with and around concrete pumpers.

Job Hazard Analysis JHA Suffix Number: 13-1647

Mar 02, 2017 · Job Hazard Analysis JHA Suffix Number: 13-1647 Revision:6 JHA No. FBP-JHALiming47 Revision No. 6 General or Job-Specific General JHA Issue Date 3/2/2017 Expiration Date NA Description of Work General Work JHA Addresses common (neither unique nor substantial hazard) work activities conducted by FBP and its Construction Support Contractor.

eLCOSH : Power Line Hazard Awareness

Power line contacts involving concrete pumps seem to occur during the take-down phase. True or false? If a power line is not de-energized, and barrier protection has D.Q1 been installed on the line, the closest distance that a crane boom or load line can (safely) be to a power line less than 50kV is ____________feet.

Concrete Delivery Requirements Safety Data Sheet

Power Lines Open Area Outside 6.4m of Power Lines 2. power lines *Note: the 0.9 separation distance relates to the following activities: • Vehicles driving under power lines • Trucks discharging while parked under power lines • Vehicles and personnel passing under power lines that connect a domestic house to power lines.

Power Line Hazards Awareness

Chapter 1 – Introduction to Power Line Hazards 2??Workers installing a chain link fence directly under an overhead power line were electrocuted when one of the workers raised a long section of top rail and brought it into contact with the line. ??The boom of a concrete pump contacted overhead power lines as it was guided over a pour.

Power Line Hazards Awareness

May 02, 2013 · The "American Concrete Pumping Association Safety Manual" (to address stability and ground support hazards such as tipping hazards, improper outrigger positioning, and inadequate soil conditions. In your letter, you expressed several concerns about concrete pump operators who are distracted from operations because of the use of cell phones or other mobile communications devices.

Job Description Hazard Identification Hazard Controls

Placing Concrete 1. Positioning concrete pumper and redi-mix trucks 1. Workers run over/backed into by equipment a. While heavy equipment is operating, all workers on the ground will wear hi-visibility vests and hardhats. 2. Placing concrete as it comes from the hose 2. Air in line causing high-speed burst of concrete b. Concrete pumpers and

Concrete pumping | Safe Work Australia

Sep 10, 2021 · line pumps, using trailer or truck-mounted pumps with flexible hoses; Some control measures for common hazards in concrete pumping operations are listed below. You must use control measures specific to the hazards at your workplace. Potential hazards and control measures are not limited to those listed. Hazard: Overhead power lines.

Keeping out of power lines'way - Concrete Construction

The American Concrete Pumping As-sociation urges these safety mea-sures near power lines: Stay alert. Look for power lines wherever you operate a boom pump. Keep the remote control on the pump truck when operating near power lines. If the boom hits a power line, the remote control ca-ble and operator are a quick path for the electricity to